Reactive airways dysfunction syndrome caused by bromochlorodifluoromethane from fire extinguishers.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 15258280.
- Also identified by PMC identifier 1740836.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Although the neurological and cardiovascular effects of Freons have been extensively described, the respiratory effects have been less well documented. We report four cases of occupational asthma following accidental exposure to bromochlorodifluoromethane (Halon 1211) due to release of the contents of a fire extinguisher. All subjects developed an irritative reaction of the upper airways and lower respiratory symptoms immediately after exposure. Non-specific bronchial hyperreactivity was present for at least two months in all subjects and was still present more than two years after exposure in one case. The diagnosis of reactive airways dysfunction syndrome can be adopted in at least three of these four cases.
Medical subject headings
- Asthma
- Chlorofluorocarbons, Methane
- Fire Extinguishing Systems
- Flame Retardants
- Occupational Diseases