The Meixner test in the detection of alpha-amanitin and false-positive reactions caused by psilocin and 5-substituted tryptamines.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 15278082.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The Meixner test has been suggested to identify the presence of alpha-amanitin, one of the toxic compounds in Amanita mushrooms. We attempted to determine the detection limit of the Meixner test for alpha-amanitin and to determine the percentage of positive sample interpretation compared with other mushroom indole compounds. This was a 2-part in vitro experiment. In part 1, we applied the Meixner test to a series of dilutions of alpha-amanitin (0 microg, 0.8 microg, 1.0 microg, 2.0 microg, and 4.0 microg) on telephone book paper, which were then presented to 5 blinded emergency physicians. We sought to determine the lowest amount of alpha-amanitin that was universally recognized as positive by the physicians (the detection limit). In the second part, 5 emergency physicians were presented simultaneously with 10 Meixner processed samples, including the mushroom indole compounds alpha-amanitin (2 microg and 10 microg), psilocin (20 microL and 60 microL of mushroom extract), 5-hydroxytryptamine (100 microg and 200 microg), and 5-methoxy-N,N-dimethyltryptamine (100 microg and 200 microg), as well as 2 negative controls (20 microL of water and methanol). We determined how likely these other indoles are to be mistaken for a positive alpha-amanitin Meixner reaction result by determining the percentage of positive sample interpretation for each compound and comparing them with the rate for alpha-amanitin. Fisher's exact test was used to determine any significant difference (P<.05) between the samples. The minimum amount of alpha-amanitin that was identified with 100% agreement by testers was 2 microg. For the second part, there was 100% agreement that psilocin gives a positive Meixner test (100% false positive) and a 35% recognition rate of the 5-substituted tryptamine compounds as a positive Meixner test. There was no statistical difference between the interpretation of alpha-amanitin and psilocin, suggesting the test is unable to differentiate between them. Although the Meixner test has a good detection limit for toxic amounts of alpha-amanitin, a positive Meixner reaction does not adequately distinguish between alpha-amanitin and other mushroom indoles.
Medical subject headings
- Agaricales
- Amanitins
- Psilocybin