Arthroscopic treatment of type III tibial spine fractures using absorbable fixation.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 15315048.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Over 2 years, five patients (average age 15 years) were diagnosed with a type III tibial spine fracture. All five fractures were treated with arthroscopic reduction and internal stabilization using absorbable fixation. At average 8.5-year follow-up, patients were interviewed and examined. Results were documented regarding function, KT-1000 testing, range of motion, and radiographic findings. All five patients reported no functional limitations despite participation in high-demand sports. Stability testing by KT-1000 revealed no objective instability. Range of motion was normal when the knee was immobilized in full extension postoperatively. No radiographic abnormality was noted at follow-up.
Medical subject headings
- Arthroscopy
- Fracture Fixation, Internal
- Tibial Fractures
Anatomy
- knee
- tibia