Nephrotoxicity of high-osmolality versus low-osmolality contrast media: randomized clinical trial.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 1535876.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The comparative frequency of and risk factors for nephrotoxicity with low-osmolality contrast medium (LOM) versus high-osmolality contrast medium (HOM) were investigated. A randomized, double-blind clinical trial was conducted in patients undergoing diagnostic angiocardiography (n = 430) or contrast material-enhanced body computed tomography (CT) (n = 499). Nephrotoxicity was defined as an increase in serum creatinine level that was greater than both 33% and 0.4 mg/dL (40 mumols/L) above the baseline level within 48 hours after the radiologic procedure. The frequency of nephrotoxicity was similar in patients who received LOM versus those who received HOM: 13 of 479 (2.7%) versus 13 of 450 (2.9%), respectively (P = .87), overall; 4.4% versus 4.0% in angiocardiography patients (P = .84); and 1.2% versus 2.0% in body CT patients (P = .35). Factors associated (P less than .05) with increased risk of nephrotoxicity were insulin-dependent diabetes, baseline serum creatinine level greater than 1.5 mg/dL (130 mumols/L), concurrent use of furosemide, and angiocardiographic examination. Patients who have preexisting renal insufficiency may be at higher risk for nephrotoxicity with HOM than with LOM.
Medical subject headings
- Contrast Media
- Kidney