Optimal head rotation for internal jugular vein cannulation when relying on external landmarks.
other · Level V
Where this comes from
- Record sourced from PubMed, PMID 15385337.
- Also identified by DOI 10.1213/01.ANE.0000132908.77111.CA.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
External anatomic landmarks have traditionally been used to approximate the location of the neck blood vessels to optimize central venous cannulation of the internal jugular vein (IJV) while avoiding the common carotid artery (CCA). Head rotation affects vessel orientation, but most landmark techniques do not specify its optimal degree. We simulated catheter insertion via both an anterior and central approach to the right IJV using an ultrasound probe held in the manner of a syringe and needle in 49 volunteers. Increased head rotation from 0 degrees, 15 degrees, 30 degrees, 45 degrees, and 60 degrees to the left of midline was associated with higher probability of a simulated needle contacting the IJV and the CCA. For both approaches, the risk of CCA contact was <10% for head rotations of <or=45 degrees. Increased body surface area (BSA) and body mass index (BMI) were associated with more CCA contact at head rotations of 45 degrees or 60 degrees. To optimize IJV contact while reducing the likelihood of inadvertent contact with the CCA, the head should be rotated no more than 30 degrees in patients with high BMI or BSA, but it may be turned to 60 degrees if BMI or BSA is low.
Medical subject headings
- Catheterization, Peripheral
- Head
- Jugular Veins
- Neck
- Posture