Metal-on-metal versus metal-on-polyethylene bearings in total hip arthroplasty: a matched case-control study.
case_control · Level III
Where this comes from
- Record sourced from PubMed, PMID 15457416.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This case-control study was performed to investigate the hypothesis that metal-on-metal (M-M) bearings reduce the risk of aseptic component loosening when compared with metal-on-polyethylene (M-PE) bearings. Cases were identified from a computerized joint database as patients who had received a primary total hip arthroplasty using an M-M or M-PE bearing and had documented revision or radiographic loosening of the stem or cup. Multiple controls were matched to each case for gender, age, diagnosis, hospital, operation date, follow-up, stem type, and cup design. Odds ratios were determined to identify the risk of component loosening for either bearing surface. In all, 505 cases and 1,605 controls were identified. M-M bearings demonstrated a lower risk of aseptic stem and/or cup loosening than M-PE bearings; however, this was not statistically significant.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Hip Prosthesis
- Metals
- Polyethylene
Anatomy
- hip