A cadaver model to evaluate the accuracy and reproducibility of plain radiograph step and gap measurements for intra-articular fracture of the distal radius.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 15465233.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of this study was to determine the accuracy and reproducibility of intra-articular step-off and gap displacements measured on plain radiographs using a standard cadaver model. Twenty-two physicians, in a blinded randomized fashion using a standard technique, examined the radiographs of 12 unique combinations of step and gap displacement created by a 3-part intra-articular osteotomy of the distal radius. Observer accuracy, inter- and intraobserver agreement, and tolerance limits were calculated. The results of this study suggest that observers, independent of skill level, may measure step-off and gap displacements accurately to within .62 +/- .53 mm (95% confidence interval = .59-65). The accuracy of measurement was influenced by the quality of the radiograph. Intraclass correlation coefficient scores showed "substantial" (.78) to "almost perfect" (.81) inter- and intraobserver agreement. These data can aid in the interpretation of clinical studies of acute distal radius fractures that are based on plain radiography.
Medical subject headings
- Radius Fractures
- Wrist Injuries
Anatomy
- radius
- wrist