Bispectral index and A-line AAI index as guidance for desflurane-remifentanil anaesthesia compared with a standard practice group: a multicentre study.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 15516347.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This study was designed to investigate the impact of bispectral index (BIS) or A-line AAI index (based on middle-latency auditory evoked potential) monitoring on recovery times and drug consumption when compared with standard anaesthetic practice during desflurane-remifentanil anaesthesia. After having obtained approval from the institutional review board and written informed consent, 200 adult patients undergoing minor surgical procedures were randomized to receive a desflurane-remifentanil anaesthetic controlled either solely by clinical parameters or by BIS or AAI to the following target values: during maintenance of anaesthesia to a value of '50' (BIS) or '30' (AAI), 15 min before the end of surgery to '60' (BIS) or '45' (AAI). Recovery times and drug consumption were recorded by a blinded investigator. Compared with standard practice, patients with BIS or AAI monitoring needed similar desflurane concentrations (standard practice 2.9 [0.5] vol%, BIS 3.3 [0.9] vol%, AAI 2.6 [0.5] vol%), and had similar recovery times (open eyes 5.6 [2.5] min, 5.9 [3.4] min, 5.0 [3.1] min; extubation 6.3 [2.4] min, 6.6 [3.5] min, 5.6 [3.0] min; stating name 7.3 [2.4] min, 7.6 [3.5] min, 7.3 [6.6] min). Compared with standard anaesthetic practice BIS and AAI guided titration to the used target ranges did not result in a reduction of desflurane consumption or recovery times during minor surgery with use of remifentanil.
Medical subject headings
- Anesthetics, Combined
- Electroencephalography
- Isoflurane
- Monitoring, Intraoperative
- Piperidines