Management of comminuted radial head fractures with replacement arthroplasty.
review · Level V
Where this comes from
- Record sourced from PubMed, PMID 15539098.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Radial head arthroplasty is indicated for displaced comminuted radial head fractures that cannot be managed reliably with open reduction and internal fixation and that have an associated elbow dislocation. Replacement also is indicated in patients with comminuted radial head fractures that have or are likely to have a disruption of the medial col-lateral, lateral collateral, or interosseous ligaments. Biomechanical studies have demonstrated that metallic implants restore elbow stability similar to the native radial head. The early and midterm clinical experience with metallic radial head arthroplasty has been encouraging relative to earlier reports with silicone devices. Newer modular designs incorporate improved sizing to better reproduce the anatomy of the proximal radius and are easier to insert intraoperatively.
Medical subject headings
- Arthroplasty, Replacement
- Elbow Joint
- Fractures, Comminuted
- Radius Fractures
Anatomy
- elbow
- radius