The effect of glycine filler on the elution rate of gentamicin from acrylic bone cement: a pilot study.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 15552132.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Elution of antibiotics from acrylic bone cement (polymethylmethacrylate [PMMA]) is dependent on the access of fluid to the depths of the cement that contains the antibiotic. Commercially prepared antibiotic beads that are porous have higher elution rates than hand-mixed, nonporous antibiotic PMMA mixtures. To increase the elution of gentamicin from hand-mixed PMMA, glycine was added as a filler to produce porosity. Elution of gentamicin from the antibiotic PMMA-glycine mixture increased with increasing amounts of glycine. With 3.6 g gentamicin powder and 14 g of crystalline glycine per batch of Palacos PMMA, the elution of gentamicin from the PMMA at 2 days was, similar to the previously documented elution of gentamicin from commercially prepared porous Septopal PMMA beads. With further investigation it may be possible to identify a specific filler and a volume of filler that can be hand mixed in antibiotic PMMA to produce the elution behavior that is needed for specific clinical requirements.
Medical subject headings
- Anti-Bacterial Agents
- Bone Cements
- Gentamicins
- Glycine
- Polymethyl Methacrylate