Helical plate fixation for treatment of comminuted fractures of the proximal and middle one-third of the humerus.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 15589919.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
When an operative treatment is indicated for comminuted fractures of the proximal and middle one-third of the humerus, plate fixation is one of the better options. However, a long plate must be applied from the lateral aspect of the greater tuberosity to the shaft of the humerus, which requires dissection of the deltoid muscle insertion. We twisted the long plate and fixed it from the lateral aspect of the greater tuberosity to the anterior or antero-medial aspect of the mid or the distal shaft of the humerus preserving the deltoid muscle insertion in nine patients (10 limbs). Eight out of 10 cases involved comminuted segmental fractures of the proximal humeral shaft, the surgical neck, and the greater tuberosity. Tricortical autoiliac bone graft was necessary in two patients to restore the neck-shaft angle. All fractures healed uneventfully at 19 weeks on average without additional procedure (range: 14-28 weeks). Shoulder function was evaluated according to Neer's criteria. Three patients were classified as excellent, five satisfactory, and as two unsatisfactory, there was no failure.
Medical subject headings
- Bone Plates
- Fracture Fixation, Internal
- Fractures, Comminuted
- Humeral Fractures