Validation of the Adult OMNI Scale of perceived exertion for walking/running exercise.
other · Level V
Where this comes from
- Record sourced from PubMed, PMID 15595300.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Concurrent and construct validity of the OMNI-Walk/Run Scale of Perceived Exertion was examined using young adult women and men (18-36 yr). Concurrent validity was established by correlating OMNI-Walk/Run Scale ratings of perceived exertion (RPE-OMNI) with oxygen uptake (VO2), relative maximal oxygen uptake (%VO2(max)), ventilation (VE), respiratory rate (RR), respiratory exchange ratio (RER), and heart rate (HR) to a graded exercise test on a treadmill. Construct validity was established by correlating RPE-OMNI with RPE from the Borg (6-20) Scale (RPE-BORG). Measurements were made every min throughout the test. The range of exercise responses across the incremental walking/running test for the female and male groups were: VO2 = 0.99-3.9 L x min(-1), HR = 98-190 beats x min(-1) and RPE-OMNI = 1.3-9.4. Correlation/regression analyses indicated that RPE-OMNI distributed as a positive linear function for all criterion measures; r = 0.67 to 0.88 (P < 0.05). RPE-OMNI was positively and linearly related to the RPE-BORG; r = 0.96 (P < 0.01) for both the female and male groups. Concurrent and construct evidence supports use of the OMNI-Walk/Run Scale by adult women and men to estimate RPE during graded exercise test on a treadmill.
Medical subject headings
- Exercise
- Exercise Test
- Perception
- Physical Exertion