Clinical cross-over comparison of mid-dilution hemodiafiltration using a novel dialyzer concept and post-dilution hemodiafiltration.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 15610261.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Several studies have indicated that the improved elimination of middle molecules by convective renal replacement procedures might be associated with a better outcome in end-stage renal disease (ESRD). On-line mid-dilution hemodiafiltration (HDF) with the Nephros OLpur MD 190 hemodiafilter represents a novel extracorporeal renal replacement therapy concept to increase the removal of middle molecules. In a prospective cross-over study in 10 ESRD patients, this technique was compared to on-line post-dilution HDF with a conventional synthetic high-flux dialyzer, operated at its technical limit, concerning small and middle molecular solute removal. Each patient was treated 3 times for 4.0 +/- 0.4 hours with both filters. Blood flow was 400 mL/min, substitution flow (Q(S)) during mid-dilution HDF 200 mL/min, and during post-dilution HDF 100 mL/min, and effective dialysate flow of 700 - Q(S) mL/min. Instantaneous clearances, reduction ratios (RR), and middle molecule mass transfer in continuously collected dialysate were determined. While urea and creatinine clearances were significantly lower (6.4% and 3.9%, respectively), middle molecule removal was much more efficient in mid-dilution HDF over the whole range of investigated proteins: compared to post-dilution HDF, beta(2)-microglobulin (11.8 kD) clearance (165.8 +/- 26.59 vs. 201.9 +/- 20.63 mL/min; P < 0.001), RR (80.0 +/- 5.4% vs. 82.2 +/- 5.7%; P < 0.001), and dialysate mass transfer (53% higher; P < 0.001) were significantly higher. For the larger middle molecules, cystatin C (13.4 kD) and retinol-binding protein (21.2 kD), mid-dilution HDF resulted in an even more superior performance, indicated by significantly higher values of all investigated parameters. On-line mid-dilution HDF with the Nephros OLpur MD 190 hemodiafilter appears to be a true technologic step ahead in terms of improved middle molecule removal. This efficient procedure gives hope to play a role in preventing or at least retarding dialysis-related long-term complications, such as beta(2)m amyloidosis, in ESRD patients, and may contribute to a more adequate dialysis therapy.
Medical subject headings
- Hemodiafiltration
- Kidney Failure, Chronic