A multicentre evaluation of the Medtronic AVE Flexible Iliac Bridge Stent in the iliac arteries (the first study).

Gaines, P A; Schulte, K-L; Müller-Hülsbeck, S; Seelen, J; Maleux, G; van Overhagen, H; Cleveland, T J · Eur J Vasc Endovasc Surg · 2005

prospective_cohort · Level II

Where this comes from

Abstract

To investigate the short term and 6 month outcomes of a recently introduced iliac stent (the Medtronic AVE Flexible Iliac Bridge Stent). One hundred and sixteen patients, 122 limbs from 6 European sites with atherosclerotic occlusive disease were included if they either had a full occlusion or there was a residual gradient >10 mmHg following PTA. Clinical, haemodynamic and Duplex outcomes were recorded to 6 months. After stent placement there was no residual stenosis >30 and 8.1% of segments had a residual resting gradient of >10 mmHg. There were three local complications and three deaths at 30 days. Primary patency at 30 days and 6 months was 94.1 and 82.7%. Marked clinical improvement occurred in 87.6 and 86.2% at 30 days and 6 months. The Medtronic AVE iliac stent has good 30 day and 6 months outcomes supporting the effective use of this device in occlusive disease.

Medical subject headings