Repair of exposed porous polyethylene implants utilizing flaps from the implant capsule.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 15745784.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To determine the feasibility of the use of flaps from the capsule surrounding porous polyethylene implants in repairing large or recurrent implant exposures. Retrospective, noncomparative, interventional case series. Sixteen patients with exposed porous polyethylene implants. Vertical and horizontal flaps were created from the implant capsule. These flaps were used to create a double layer of closure to seal the exposure. All patients had a minimum follow-up of at least 12 months. Repair of the exposure without recurrence during the follow-up interval, and assessment of complications. At the last follow-up visit, the socket was completely healed in all but 2 patients. In 1 of them, the implant was subsequently exchanged. Other complications included motility loss, conjunctival cyst, and granuloma formation. The use of the implant capsule to salvage exposed porous polyethylene implants is an effective technique; it is associated with some complications that can be minimized by careful case selection.
Medical subject headings
- Foreign-Body Migration
- Ophthalmologic Surgical Procedures
- Orbital Implants
- Polyethylene
- Surgical Flaps