Atrial overdrive pacing in patients with sleep apnea with implanted pacemaker.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 15750043.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Atrial overdrive pacing markedly improved sleep-disordered breathing in a recent study. Using a single-blind, randomized, crossover design, we aimed to reproduce these findings and investigate the possible underlying mechanisms. Twenty ambulatory patients with an implanted pacemaker or cardioverter defibrillator were studied by polysomnography on 3 consecutive nights in a randomized, single-blind, crossover study in which devices were programmed for nonpacing or for overdrive pacing at 7 or 15 beats/minute faster than the mean nocturnal heart rate. Ventilation and biomarkers (urinary norepinephrine excretion, amino-terminal portion of the precursor of brain natriuretic peptide, or NT-proBNP, were also evaluated. Neither the primary endpoint apnea-hypopnea index, nor the apnea index, oxygen desaturation, ventilation, or biomarkers were affected by the nocturnal atrial overdrive pacing. A small, clinically insignificant, rate-dependent reduction in the hypopnea index was evoked by pacing (nonpacing, 13.4 +/- 1.4; pacing 7, 12.9 +/- 1.4; pacing 15, 10.9 +/- 1.0; p < 0.01, analysis of variance). The lack of effect on the apnea-hypopnea index means that atrial overdrive pacing is inappropriate for treating sleep-disordered breathing.
Medical subject headings
- Cardiac Pacing, Artificial
- Pacemaker, Artificial
- Sleep Apnea Syndromes