Surgical management of a long segmental defect of the humerus using a cylindrical titanium mesh cage and plates: a case report.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 15758677.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This is a case report of a patient who sustained multiple gunshots resulting in a Gustilo Anderson type IIIB mid-shaft humeral fracture associated with extensive segmental bone and soft-tissue loss. The patient was treated initially by multiple irrigations, wound debridement, and a unilateral external fixator. After the soft tissue healed without infection, the mid-shaft humeral defect of approximately 8 cm segmental bone loss was reconstructed with a cylindrical titanium mesh cage packed with a composite of cancellous allograft and demineralized bone matrix putty and stabilized with limited contact dynamic compression plates. At 13 months follow-up, plain radiographs demonstrated a healed construct with good alignment, and computed tomography images demonstrated bony in-growth through the cage. The patient had full range of motion at the shoulder and the elbow. This technique may be a reasonable alternative when treating large segmental bone defects of the humerus.
Medical subject headings
- Bone Plates
- Humeral Fractures
- Surgical Mesh
- Wounds, Gunshot
Anatomy
- humerus