Assessing fluid-responsiveness by a standardized ventilatory maneuver: the respiratory systolic variation test.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 15781502.
- Also identified by DOI 10.1213/01.ANE.0000146939.66172.AE.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Respiratory-induced changes in arterial blood pressure predict fluid responsiveness. However, the accuracy of these variables is affected by the preset tidal volume and by the early inspiratory increase in arterial blood pressure. We have therefore calculated the slope produced by the minimal systolic blood pressures (plotted against the respective airway pressures) during a ventilatory maneuver consisting of four incremental, successive, pressure-controlled breaths, termed the Respiratory Systolic Variation Test (RSVT). In 14 ventilated patients, after major vascular surgery, the slope of the RSVT decreased significantly after intravascular fluid administration and correlated with the end-diastolic area and with changes in cardiac output better than filling pressures. This preliminary study suggests that a standardized ventilatory maneuver may be useful in guiding fluid therapy in ventilated patients.
Medical subject headings
- Body Fluids
- Respiration, Artificial
- Respiratory Function Tests
- Respiratory Mechanics