Maternal death after second-trimester genetic amniocentesis.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 15863586.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We report a maternal death after a second-trimester amniocentesis. An uncomplicated amniocentesis was performed using sterile technique and ultrasound guidance. A refrigerated amniotic fluid specimen demonstrated negative leukocyte esterase activity, negative Gram stain for bacteria and white blood cells, and normal glucose and interleukin-6. The patient died from Escherichia coli sepsis and disseminated intravascular coagulation 40 hours after the amniocentesis. The autopsy showed normal- appearing needle entries into the skin and uterus without evidence of bowel adhesion or a needle track through the bowel. Genetic counselors and obstetric care providers should be aware of potential serious maternal morbidity and mortality that may occur subsequent to uncomplicated amniocentesis.
Medical subject headings
- Amniocentesis
- Bacteremia
- Escherichia coli
- Escherichia coli Infections