Femoral neck fractures complicating metal-on-metal resurfaced hips: a report of 2 cases.

Sharma, H; Rana, B; Watson, C; Campbell, A C; Singh, B J · J Orthop Surg (Hong Kong) · 2005

case_report · Level V

Where this comes from

Abstract

Metal-on-metal hip resurfacing arthroplasty is increasingly popular for younger patients with advanced hip disease. Intra-operative or immediate postoperative femoral neck fracture after metal-on-metal hip resurfacing is a well-described technical complication, ranging from 0% to 1.5%. We report 2 cases of late femoral neck fracture occurring 8 and 15 months following the index operation, with a review of the literature. We recommend that patient selection should be of prime importance before embarking on metal-on-metal surface hip replacement to avoid such complications.

Medical subject headings

Anatomy