Possible air embolism during eye surgery.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 15920190.
- Also identified by DOI 10.1213/01.ANE.0000154304.63828.C0.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We report a case of possible air embolism during a three-port pars plana vitrectomy and air-fluid exchange of the vitreous cavity of the eye. After the start of intraocular air flushing, sudden tachycardia, a decrease in oxygen saturation and end-tidal carbon dioxide tension, and a distinct "mill-wheel" murmur were observed. Venous air embolism was suspected but other sources of air entry into the circulation and a thromboembolic event were excluded. Once intraocular air flushing was ceased, clinical variables returned to normal within minutes. In conclusion, during air-fluid exchange of the vitreous cavity, air embolism should be considered as a possible rare complication.
Medical subject headings
- Embolism, Air
- Intraoperative Complications
- Ophthalmologic Surgical Procedures