Comparing uterine electromyography activity of antepartum patients versus term labor patients.
case_control · Level III
Where this comes from
- Record sourced from PubMed, PMID 16021054.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of this study was to compare uterine electromyography of patients delivering>24 hours from measurement with laboring patients<or=24 hours from measurement. Fifty patients (group 1: labor, n=24; group 2: antepartum, n=26) were monitored using transabdominal electrodes. Group 2 was recorded at several gestations. Uterine electrical "bursts" were analyzed by power-spectrum from 0.34 to 1.00 Hz. Average power density spectrum (PDS) peak frequency for each patient was plotted against gestational age, and compared between group 1 and group 2. Frequency was partitioned into 6 bins, and associated burst histograms compared. Group 1 was significantly higher than group 2 for gestational age (39.87+/-1.08 vs 32.96+/-4.26 weeks) and average PDS peak frequency (0.51+/-0.10 vs 0.40+/-.03 Hz). Histograms were significantly different. A correlation coefficient of .41, with significance, was found with PDS vs gestation. Uterine electromyography in antepartum patients is significantly lower than in laboring patients delivering<or=24 hours from measurement.
Medical subject headings
- Electromyography
- Labor, Obstetric
- Pregnancy
- Uterus