Numerical confusion errors in ishihara testing: findings from a population-based study.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 16038669.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To describe the prevalence of numerical confusion errors in Ishihara testing in a representative sample of Australian children. Cross-sectional, population-based study. The Sydney Myopia Study examined a representative stratified random cluster sample of 1,741 children (aged 6 years) attending 34 schools in Sydney, Australia (response rate, 78.9%), including color vision tests in 1,735 children. Those with any color vision defects (n = 33; 1.9%; 97% boys) were excluded. Responses for each Ishihara plate were recorded. Numerical confusion errors were made by 75.8% of children with normal color vision; there was no gender difference. Plates 3 and 7 were particularly prone to numerical confusion errors; 48.4% and 40.8%, respectively, of children misread these plates. Numerical confusion errors in the Ishihara test were relatively common in children with normal color vision. The frequency of such errors could indicate an inherent deficiency in this commonly used test.
Medical subject headings
- Color Perception
- Color Perception Tests
- Diagnostic Errors