Detection of coronary stenoses at rest with myocardial contrast echocardiography.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 16103241.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We hypothesized that autoregulatory changes in arteriolar blood volume (aBV) that develop distal to a stenosis can be measured with myocardial contrast echocardiography, allowing coronary stenosis detection at rest without recourse to stress. Patients with varying degrees of coronary artery stenosis on quantitative angiography underwent high-mechanical-index myocardial contrast echocardiography at 15 Hz to allow measurement of phasic changes in aBV in large intramyocardial vessels using either Definity (group 1; n=22) or Imagent (group 2; n=22). Progressive increases in the <0.001) and group 2 (0.10+/-0.05, 0.27+/-0.18, 0.39+/-0.28, and 0.74+/-0.37; P<0.0001) patients. A systolic/diastolic aBV signal ratio of >0.34 provided a sensitivity and specificity of 80% and 71%, respectively, for the detection of >75% coronary stenosis in group 1 patients, whereas a ratio of >0.43 provided a sensitivity and specificity of 89% and 74%, respectively, for the detection of >75% stenosis in group 2 patients. Both the presence and severity of a physiologically significant coronary stenosis can be detected at rest by measuring the increase in aBV on myocardial contrast echocardiography that occurs distally to the stenosis without recourse to any form of stress.
Medical subject headings
- Contrast Media
- Coronary Stenosis
- Echocardiography
- Rest