Effect of hydroxyapatite-coated tibial components on changes in bone mineral density of the proximal tibia after uncemented total knee arthroplasty: a prospective randomized study using dual-energy x-ray absorptiometry.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 16124970.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Sixteen patients scheduled for an uncemented total knee arthroplasty (TKA) were randomized to receive a tibial component either with (n = 8) or without (n = 8) hydroxyapatite (HA) coating. In 4 regions of interest, prospective measurements of bone mineral density (BMD) using dual-energy x-ray absorptiometry were performed in the proximal tibia. Two years after the operation, the only significant change in BMD was in the lateral tibial condyle, where BMD had increased by 6.1% (95% confidence interval: 2.3%-9.9%) in patients with tibial components without HA. The intragroup changes (0-24 months) in the uncoated group and HA-coated group were significantly different (P = .003) in these regions of interest. There was no significant effect of HA coating on bone remodeling pattern of the proximal tibia.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Bone Density
- Durapatite
- Tibia
Anatomy
- knee
- tibia