Isolated acetabular revision through the posterior approach: short-term results after revision of a recalled acetabular component.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 16139708.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Isolated acetabular revision is commonly associated with high rates of postoperative dislocation. We hypothesize that the dislocation rate in a series of isolated acetabular revisions for loosening of recalled acetabular components is low when strict intraoperative stability testing is coupled with re-repair of the piriformis tendon. Twenty-six isolated revisions of aseptic, loose recalled acetabular components were performed through the posterior approach by a single surgeon. All piriformis tendon and posterior capsular repairs from the index operation were considered intact at the time of revision. The piriformis tendon was re-repaired in each revision case. The average revision acetabular component was 3 mm larger than the index component. In this select group of isolated acetabular revisions, strict intraoperative stability testing and re-repair of the piriformis tendon yielded zero dislocations.
Medical subject headings
- Acetabulum
- Hip Prosthesis
Anatomy
- hip
- pelvis