Assessment of a customised immobilisation system for head and neck IMRT using electronic portal imaging.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 16154217.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To evaluate set-up reproducibility of a cabulite shell and determine CTV-PTV margins for head and neck intensity-modulated-radiotherapy. Twenty patients were entered into the study. A total of 354 anterior and lateral isocentric electronic portal images (EPIs) were compared to simulator reference images. About 94% of all translational displacements were < or =3 mm, and 99% < or =5 mm. The overall systematic error was 0.9 mm (+/-1.0SD) in the Right-Left, 0.7 mm (+/-0.9SD) in the Superior-Inferior and -0.02 mm (+/-1.1SD) in the Anterior-Posterior directions. The corresponding SDs of the random errors were +/-0.4, +/-0.6 and +/-0.7 mm. The estimated margins required from CTV-PTV were calculated according to the Van Herk formula was 2.9, 2.6 and 3.3 mm, respectively. This head and neck immobilisation system is of sufficient accuracy for its use with IMRT treatments and a 3 mm CTV-PTV margin has been adopted.
Medical subject headings
- Head and Neck Neoplasms
- Immobilization