Clinical significance of fractional flow reserve for evaluation of functional lesion severity in stent restenosis and native coronary arteries.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 16162770.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
OBJECTIVE: Fractional flow reserve (FFR) is a valid surrogate for hemodynamic significance in stenotic native coronary arteries, but its validity in patients with coronary stent restenosis is unknown. DESIGN: Prospective. SETTING: University hospital. PATIENTS: We studied 42 patients (mean age +/- 1 SD, 62 +/- 10 years) with stent restenosis and 57 patients (mean age, 61 +/- 12 years) with a native coronary lesion. All patients demonstrated a single coronary lesion of intermediate severity (stenosis diameter, 40 to 70%). Determination of FFR and quantitative angiography of the stenosis were performed. RESULTS: Stenosis diameter was comparable in both groups (native, 52 +/- 11%; stent, 52 +/- 9%; not significant [NS]). FFR was lower in stent restenosis (0.77 +/- 0.15 vs 0.82 +/- 0.12, p < 0.05) and more often pathologic with an FFR < 0.75 (48% vs 26%, p < 0.05) compared to native coronary stenosis. However, the area under the receiver operating characteristic curve for native stenosis was 0.82 (95% confidence interval [CI], 0.71 to 0.94) and for stent restenosis was 0.84 (95% CI, 0.71 to 0.97; NS). In patients with an FFR > 0.75, there was no adverse coronary event that was related to the stented lesion in the subsequent 6 months. CONCLUSIONS: The threshold of stenosis diameter of coronary lesions for pathologic FFR measurement (FFR < 0.75) is similar for stent restenosis and native coronary stenosis. Thus, FFR measurement seems to be applicable for decision making in patients with stent restenosis.
Medical subject headings
- Angioplasty, Balloon, Coronary
- Coronary Stenosis
- Stents