Olecranon fracture fixation utilizing a bioabsorbable tension band construct: analysis of stability with motion in a cadaveric model.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 16200023.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This study was performed to determine if tension band suturing with bioabsorbable materials can maintain fracture (osteotomy) reduction when subjected to an early motion protocol. Olecranon osteotomies were created in 13 cadaveric upper extremities and then sequentially fixed with axial Kirschner wires, and tension band wiring/suturing utilizing: musical #1 PDS (Ethicon Inc., Somerville, New Jersey, USA), musical #1 Panacryl (Ethicon Inc.), musical #2 Panacryl (Ethicon Inc.), and 18 gauge surgical wire. Specimens were cycled through a range of motion in a continuous passive motion machine. Specimens fixed with K-wires only, musical #1PDS and musical #1 Panacryl tension band suturing failed to maintain osteotomy reduction. Only surgical steel and musical #2 Panacryl maintained osteotomy reduction; both were superior to the other fixation methods (P<0.001). The musical #2 Panacryl suture is an excellent choice for a tension band suture construct; it retains 80% of its breaking strength at 3 months, is fully absorbed, and maintains osteotomy reduction throughout a passive motion protocol.
Medical subject headings
- Absorbable Implants
- Elbow Joint
- Fracture Fixation, Internal
- Internal Fixators
- Joint Instability
- Ulna Fractures
Anatomy
- elbow
- ulna