Histopathologic findings of retrieved specimens of vertebroplasty with polymethylmethacrylate cement: case control study.
case_control · Level III
Where this comes from
- Record sourced from PubMed, PMID 16205333.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Case control study. To investigate the histopathologic findings of 2 retrieved specimens from failed vertebroplasty with polymethylmethacrylate (PMMA) cement. Vertebroplasty using PMMA cement has been commonly used to treat debilitating back pain from compression fracture, angiomas, and metastatic cancer. However, there was concern about the unpredictable future results with PMMA cement. The histopathologic changes were rarely reported. There were 2 PMMA augmented and 3 nonaugmented fractured vertebral bodies retrieved for histopathologic study. Between the 2 groups, we compared the findings of bone necrosis, foreign body reaction, fibrotic wall formation, and neovascularization. Bone necrosis was noted in the periphery of PMMA cement, which was surrounded by fibrotic tissues. In contrast, no fibrotic wall formation could be found in the nonaugmented control group. Foreign body reaction was only noted in PMMA augmented cases, and neovascularization was only noted in the control cases. PMMA cement might not be as bioinert as we considered. Therefore, the long-term safety of vertebroplasty should be further evaluated.
Medical subject headings
- Arthroplasty
- Bone Cements
- Lumbar Vertebrae
- Polymethyl Methacrylate
- Spinal Fractures
- Thoracic Vertebrae
Anatomy
- lumbar spine
- thoracic spine