Interexaminer repeatability of antidromic ulnar sensory nerve conduction velocity measurements.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 16213252.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To determine the interexaminer repeatability of the ulnar antidromic sensory nerve conduction velocity (NCV). Test-retest design. Based on a randomization list of various combinations and sequences from 2 of a total of 3 examiners, the measurement was repeated within half an hour by a second examiner blinded to the results of the first examiner. Outpatient department. Twenty-four consecutive healthy subjects (mean age, 38 y). Not applicable. The intraclass correlation coefficient (ICC) and the coefficient of repeatability (CR) were determined for the below elbow to wrist (BE-to-W), above elbow to below elbow (AE-to-BE), and axilla to above elbow (AX-to-AE) segments. The ICC was .42 for the BE-to-W, .15 for the AE-to-BE, and -.05 for the AX-to-AE segment. The CR was 12.2m/s for the BE-to-W, 16.2m/s for the AE-to-BE, and 21.4m/s for the AX-to-AE segment. During the assessment of the antidromic sensory NCV of the ulnar nerve, a moderate amount of interexaminer variability must be taken into account for the BE-to-W segment. More proximally, an extremely large amount of interexaminer variability must be taken into account. This calls into question the usefulness of the antidromic ulnar sensory NCV for the AX-to-AE and AE-to-BE segments.
Medical subject headings
- Electrodiagnosis
- Neural Conduction
- Ulnar Nerve
- Upper Extremity
Anatomy
- ulna