Factors influencing range of motion after contemporary total knee arthroplasty.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 16230234.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A detailed analysis of 219 total knee arthroplasties performed with a single implant design was performed. Factors significantly affecting the postoperative range of motion of total knee arthroplasties 2 years after surgery included preoperative diagnosis and preoperative range of motion. Sex, age, body mass index, femoral component size, posterior cruciate ligament status, or fixed vs mobile bearing design did not correlate with knee range of motion 2 years postoperatively.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Knee Prosthesis
- Range of Motion, Articular
Anatomy
- knee