Brain tumors: full- and half-dose contrast-enhanced MR imaging at 3.0 T compared with 1.5 T--Initial Experience.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 16237142.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To prospectively and intraindividually compare the effect of magnetic resonance (MR) imaging at a higher magnetic field strength (3.0 T) on contrast-to-noise ratio (CNR) at different doses of a T1-shortening contrast agent in patients with contrast-enhancing brain lesions, with 1.5-T MR imaging as a reference standard. Institutional review board approval and informed consent were obtained for all patient and volunteer studies. Twelve patients (six women, six men; mean age, 58 years; range, 29-76 years) with 12 enhancing brain lesions (11 patients with primary brain tumors and one with a solitary cerebral metastasis) underwent contrast material-enhanced MR imaging three times, on three separate days: once at 1.5 T with a full dose of 0.10 mmol/kg gadopentetate dimeglumine, once at 3.0 T with a full dose, and once at 3.0 T with half that dose, 0.05 mmol/kg. The same contrast-enhanced T1-weighted spin-echo images (repetition time msec/echo time msec, 500/12; section thickness, 5 mm; matrix, 256 x 205) were obtained at both 3.0 T and 1.5 T after prior optimization of parameters at 3.0 T. The number and conspicuity of enhancing brain lesions were assessed with blinded clinical image reading. Signal-to-noise ratio and CNR were determined with region of interest analysis of enhancing lesions and normal contralateral white matter. For 3.0 T with half the standard dose and with the full dose, CNR of lesions was intraindividually compared with CNR at 1.5 T with the full dose by using the Wilcoxon matched-pairs signed rank test. At 3.0 T and full dose, CNR was 2.8-fold higher than that at 1.5 T and full dose (P < .001). At the same time, higher lesion conspicuity at clinical image reading was observed. With only half the standard dose, MR imaging at 3.0 T still yielded higher CNR (1.3-fold higher) than that with full dose at 1.5 T (P < .01). With the same amount of contrast agent, MR imaging at 3.0 T offered a significantly higher CNR of enhancing cerebral lesions, compared with that at 1.5 T; even with the dose reduced by half, CNR was still higher at 3.0 T.
Medical subject headings
- Brain Neoplasms
- Contrast Media
- Gadolinium DTPA
- Magnetic Resonance Imaging