Oxygen consumption during corridor walk testing in chronic cardiac failure.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 1623869.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We have examined the use of a 6-min corridor walk test in the assessment of functional capacity in 16 patients with chronic cardiac failure. VO2 was determined concurrently by a portable 'Oxylog'. Three tests were performed sequentially, and although there was a significant increase in distance walked and highest VO2 achieved between the first and second tests, good reproducibility was attained between the second and third tests. Both walk test variables correlated well with previously determined peak achieved VO2, and NYHA classes were separated adequately. Corridor walk testing, with or without measurement of VO2 should be a useful adjunct to maximal exercise testing in interventional studies.
Medical subject headings
- Heart Failure
- Oxygen Consumption
- Walking