Spatial variations in shear stress in a 3-D bifurcation model at low Reynolds numbers.

Rouhanizadeh, Mahsa; Lin, Tiantian C; Arcas, Diego; Hwang, Juliana; Hsiai, Tzung K · Ann Biomed Eng · 2005

biomechanical · Level V

Where this comes from

Abstract

Real-time wall shear stress is difficult to monitor precisely because it varies in space and time. Microelectromechanical systems sensor provides high spatial resolution to resolve variations in shear stress in a 3-D bifurcation model for small-scaled hemodynamics. At low Reynolds numbers from 1.34 to 6.7 skin friction coefficients (C(f)) varied circumferentially by a factor of two or more within the bifurcation. At a Reynolds number of 6.7, the C(f) value at the lateral wall of the bifurcation along the 270 degree plane was 7.1, corresponding to a shear stress value of 0.0061 dyn/cm(2). Along the 180 degree plane, C(f) was 13 or 0.0079 dyn/cm(2), and at the medial wall along the 90 degree plane, C(f) was 10.3 or 0.0091 dyn/cm(2). The experimental skin friction coefficients correlated with values derived from the Navier-Stokes solutions.