Detection of thrombus in acute ischemic stroke: value of thin-section noncontrast-computed tomography.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 16269650.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Previous studies on the hyperdense middle cerebral artery (MCA) sign were conducted using > or =5-mm thickness noncontrast-computed tomography (NCT). The purpose of this study was to compare thin-section NCT with 5-mm NCT in the detection of thrombus in acute ischemic stroke. Enrolled were consecutive 51 patients with acute infarction in the anterior or MCA territory. All patients underwent both 5-mm NCT and either 1.25- or 1-mm thin-section helical NCT within 6 hours of symptom onset. Patients were assigned to either the single or multisegmental occlusion group, depending on the thrombus extent on thin-section NCT. Thin-section NCT and 5-mm NCT were compared in the detection of thrombi. Thrombi were identified in 45 patients (88%) on thin-section NCT and 16 on 5-mm NCT (31%; P<0.001). No occlusion was seen in 6 patients. Both sensitivity and specificity of thin-section NCT in detection of thrombus were 100%. Acute thrombus can be detected with higher sensitivity on thin-section NCT than on 5-mm NCT, and its extent is more accurately determined on thin-section NCT.
Medical subject headings
- Brain Ischemia
- Intracranial Thrombosis
- Stroke
- Tomography, X-Ray Computed