Evaluation of a new algorithm to determine the hip joint center.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 16271596.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Accurately locating the hip joint center is a challenging and important step in many biomechanical investigations. The purpose of this study was to test the accuracy and robustness of a "pivoting" algorithm used to locate the hip center. We tested the performance of this algorithm with data acquired by manipulating a ball and socket model of the hip through several motion patterns. The smallest mean errors of 2.2+/-0.2 mm occurred with a circumduction motion pattern, while the largest errors of 4.2+/-1.3 mm occurred with single-plane motion (e.g., flexion/extension). Introducing random noise with an amplitude of 30 mm increased the errors by only 1.3+/-0.5 mm with a circumduction motion pattern. The pivoting algorithm performs well in the laboratory, and further work is warranted to evaluate its performance in a clinical setting.
Medical subject headings
- Algorithms
- Hip Joint
- Models, Biological