Pattern stability under cell culture conditions--a comparative study of patterning methods based on PLL-g-PEG background passivation.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 16364431.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Despite the rapidly increasing number of publications on the fabrication and use of micro-patterns for cell studies, comparatively little is know about the long-term stability of such patterns under cell culture conditions. Here, we report on the long-term stability of cellular patterns created by three different patterning techniques: selective molecular assembly patterning, micro-contact printing and molecular assembly patterning by lift-off. We demonstrate that although all three techniques were combined with the same background passivation chemistry based on assembly of a PEG-graft copolymer, there are considerable differences in the long-term stability between the three different pattern types under cell culture conditions. Our results suggest that these differences are not cell-dependent but are due to different (substrate-dependent) interactions between the patterned substrate, the passivating molecule and the serum containing cellular medium.
Medical subject headings
- Cell Culture Techniques
- Lysine
- Polyethylene Glycols