Movement variability cannot be determined reliably from no-marker conditions.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 16386261.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We sought to quantify the proportion of total variability due to movement variability in digitizing marker and no-marker conditions in treadmill running. Manually digitized markers gave variabilities in joint angles within 0.4 degrees of those from auto-tracking. Marker conditions allowed reliable estimation of movement variability by an experienced operator; the contribution of movement variability to total variability, expressed by omega-squared, had averages across the four operators of 97% for the knee angle and 93% for the hip. The no-marker condition did not allow reliable estimation of movement variability-the above figures fell, respectively, to 72% and 48%-and cannot be recommended. The group design in the marker condition produced omega-squared values of 97% knee and 91% hip, showing excellent objectivity (inter-operator reliability). However, without markers, these values fell to 47% and 15%, respectively, indicating that movement variability cannot be assessed objectively in no-marker conditions.
Medical subject headings
- Hip Joint
- Image Processing, Computer-Assisted
- Running