High-speed microfluidic differential manometer for cellular-scale hydrodynamics.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 16407104.
- Also identified by PMC identifier 1334647.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We propose a broadly applicable high-speed microfluidic approach for measuring dynamical pressure-drop variations along a micrometer-sized channel and illustrate the potential of the technique by presenting measurements of the additional pressure drop produced at the scale of individual flowing cells. The influence of drug-modified mechanical properties of the cell membrane is shown. Finally, single hemolysis events during flow are recorded simultaneously with the critical pressure drop for the rupture of the membrane. This scale-independent measurement approach can be applied to any dynamical process or event that changes the hydrodynamic resistance of micro- or nanochannels.
Medical subject headings
- Erythrocytes
- Leukocytes
- Microfluidic Analytical Techniques