Changes in amplitude-integrated electroencephalography in neonates treated with extracorporeal membrane oxygenation: a pilot study.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 16423612.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Neonates (n = 20) treated with extracorporeal membrane oxygenation were evaluated with serial amplitude-integrated electroencephalography (aEEG). There was no acute change in aEEG during extracorporeal membrane oxygenation cannulation, nor were there lateralizing effects. An abnormal aEEG predicted death or moderate to severe intracranial neuropathology with sensitivity = 1.0, specificity = 0.75, positive predictive value = 0.86, and negative predictive value = 1.0.
Medical subject headings
- Brain Injuries
- Electroencephalography
- Extracorporeal Membrane Oxygenation
- Respiratory Insufficiency