Valve replacement after T-grafting: "beating heart surgery".
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 16427902.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Patent internal thoracic and radial artery T-graft will adequately perfuse the heart during reoperation. Five of 1,023 patients with prior T-grafting had aortic (3) or mitral valve redo operations in which the heart was allowed to beat (after an initial dose of cardioplegia) during the operation without clamping the patent T-graft. Rapid resumption of cardiac function after one dose of cardioplegia and no intraoperative or postoperative evidence of myocardial infarction indicated adequacy of perfusion without apparent myocardial injury. This approach avoids injury to the T-graft from dissection and clamping, saves time, and simplifies the operation.
Medical subject headings
- Aortic Valve
- Heart Valve Prosthesis Implantation