Air ionisation and colonisation/infection with methicillin-resistant Staphylococcus aureus and Acinetobacter species in an intensive care unit.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 16432675.
- Also identified by DOI 10.1007/s00134-005-0002-8.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To determine effect of negative air ions on colonisation/infection with methicillin-resistant Staphylococcus aureus (MRSA) and Acinetobacter species in an intensive care unit. Prospective single-centre cross-over study in an adult general intensive care unit. 201 patients whose stay on the unit exceeded 48 hour's duration. Six negative air ionisers were installed on the unit but not operational for the first 5 months of the study (control period). Devices were then operational for the following 5.5 months. 30 and 13 patients were colonised/infected with MRSA and Acinetobacter spp., respectively, over 10.5 months. No change in MRSA colonisation/infection was observed compared with the 5 month control period. Acinetobacter cases were reduced from 11 to 2 (p=0.007). Ionisers may have a role in the prevention of Acinetobacter infections.