The effects of titanium and polymethylmethacrylate particles on osteoblast phenotypic stability.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 16482550.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Wear particles generated following total joint arthroplasty interact with cells at the periprosthetic margin and induce an inflammatory response that contributes to osteolysis, aseptic loosening, and implant failure. This study examined the long-term effects of particles from two commonly implanted materials, titanium (Ti) and polymethylmethacrylate (PMMA), on cell viability and metabolism over a 21-day time course, using the human osteoblast-like cell line MG-63. Addition of particles was not associated with increased cell death or nitric oxide production at the particle concentration chosen. Collagen production was increased with exposure to titanium particles, whereas alkaline phosphatase and osteocalcin expression remained unchanged following exposure to both types of particles. The data show that titanium but not PMMA particles shifts bone cell metabolism to preferentially produce fibrous tissue rather than bone.
Medical subject headings
- Biocompatible Materials
- Osteoblasts
- Polymethyl Methacrylate
- Titanium