Independent evaluation of a recently described Achilles tendon repair technique.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 16487460.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We investigated a previously reported technique for the repair of acute Achilles tendon ruptures using the percutaneous Achillon suture system (Intega Life Sciences Corporation, Plainsboro, NJ). Twenty-five patients with Achilles tendon ruptures were studied prospectively with a minimum of 12 months followup. A single 2- to 3-cm horizontal incision and the Achillon suture system were used. Early rehabilitation and an active range-of-motion brace were instituted. There were no wound problems, sural nerve injuries, or re-ruptures. All patients were able to return to their previous sporting activities by 6 months. This independent study confirms that the technique offers patients a safe operative procedure for repair of acute Achilles tendon ruptures that allows early active rehabilitation.
Medical subject headings
- Achilles Tendon
- Suture Techniques