Evaluation of a modified piezoresistive technique and a water-capsule technique for direct and continuous measurement of intra-abdominal pressure in a porcine model.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 16505660.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Intravesical pressure measurement is considered to be the gold standard for the assessment of intra-abdominal pressure. However, this method is indirect and depends on a physiologic bladder function. We evaluated a modified piezoresistive technique and a water-capsule technique for direct and continuous intra-abdominal pressure measurement. Experimental study. Animal research laboratory. Eleven male domestic pigs. In anesthetized and mechanically ventilated animals, CO2 was insufflated to stepwise increase the intra-abdominal pressure to 30 mm Hg. Pressure was then held constant for 9 hrs followed by decompression. Piezoresistive measurement and water-capsule measurement probes were placed intra-abdominally. Readings of intravesical pressure measurement, piezoresistive measurement, and water-capsule measurement were taken hourly. Mean difference to insufflator readings, confidence intervals, and limits of agreement were calculated. Differences between applied pressure and intra-abdominal pressure readings were assessed using a two-factor analysis of variance. No significant differences between methods could be observed. During stepwise pressure increase, limits of agreements were -3.6 to 3.6 mm Hg. Confidence intervals were -3.4 to 3.5 (intravesical pressure measurement), -1.6 to 1.5 (piezoresistive measurement), and 0.5 to 2.9 mm Hg (water-capsule measurement). In the presence of constantly elevated intra-abdominal pressure, limits of agreement ranged from -8.2 to +8.2 mm Hg. Confidence intervals were -0.4 to 6.2 (intravesical pressure measurement), -0.2 to 2.7 (piezoresistive measurement), and 1.1 to 5.1 mm Hg (water-capsule measurement). Both piezoresistive measurement and water-capsule measurement had smaller confidence intervals than intravesical pressure measurement, indicating higher precision, whereas water-capsule measurement had a significant offset. Piezoresistive measurement could be the most suitable device for continuous direct intra-abdominal pressure monitoring in specific patients.
Medical subject headings
- Abdomen
- Compartment Syndromes
- Manometry
- Monitoring, Physiologic
- Transducers, Pressure