Assessment of myocardial blood flow using 15O-water and 1-11C-acetate in rats with small-animal PET.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 16513617.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This feasibility study was undertaken to determine whether myocardial blood flow (MBF, mL/g/min) could be quantified noninvasively in small rodents using microPET and 15O-water or 1-11C-acetate. MBF was measured in 18 healthy rats using PET and 15O-water (MBF-W) under different interventions and compared with direct measurements obtained with microspheres (MBF-M). Subsequently, MBF was estimated in 24 rats at rest using 1-11C-acetate (MBF-Ace) and compared with measurements obtained with 15O-water. Using factor analysis, images were processed to obtain 1 blood and 1 myocardial time-activity curve per tracer per study. MBF-W was calculated using a well-validated 1-compartment kinetic model. MBF-Ace was estimated using a simple 1-compartment model to estimate net tracer uptake, K1 (K1 (mL/g/min) = MBF.E; E = first-pass myocardial extraction of 1-11C-acetate) and washout (k2 (min(-1))) along with F(BM) (spillover correction) after fixing F(MM) (partial-volume correction) to values obtained from 15O-water modeling. K1 values were converted to MBF values using a first-pass myocardial extraction/flow relationship measured in rats (E = 1.0-0.74.exp(-1.13/MBF)). In the first study, MBF-W correlated well with MBF-M (y = 0.74x + 0.96; n = 18, r = 0.91, P < 0.0001). However, the slope was different than unity, P < 0.05). Refitting of the data after forcing the intercept to be zero resulted in a nonbias correlation between MBF-W and MBF-M (y = 0.95x + 0.0; n = 18, r = 0.86, P < 0.0001) demonstrating that the underestimation of the slope could be attributed to the overestimation of MBF-W for 2 MBF-M values lower than 1.50 mL/g/min. In the second study, MBF-Ace values correlated well with MBF-W with no underestimation of MBF (y = 0.91x + 0.35; n = 24, r = 0.87, P < 0.0001). MBF can be quantified by PET using (15)O-water or 1-11C-acetate in healthy rats. Future studies are needed to determine the accuracy of the methods in low-flow states and to develop an approach for a partial-volume correction when 1-11C-acetate is used.
Medical subject headings
- Acetates
- Blood Flow Velocity
- Carbon
- Coronary Circulation
- Coronary Vessels
- Oxygen Radioisotopes
- Positron-Emission Tomography