A general solution for the time delay introduced by a low-pass Butterworth digital filter: An application to musculoskeletal modeling.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 16545388.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Low-pass Butterworth digital filters are commonly used in biomechanics-related research. In general, the input signal is filtered in the forward and reverse directions so that a temporal shift in the output signal does not occur. There are times, however, when introducing a specific time delay is an important consideration when modeling a physiological event. Filtering the data in the forward direction only can be used as an efficient method to account for a specific time delay. Specific delays are possible by carefully selecting the filter order and cut-off frequency. The purpose of this paper is to present the analytical formulation of a general solution for the time delay introduced by a low-pass Butterworth digital filter.
Medical subject headings
- Biophysics
- Models, Biological
- Musculoskeletal Physiological Phenomena
- Musculoskeletal System