Posterior vaginal sling experience in elderly patients yields poor results.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 16579942.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The objective of the study was to evaluate our experience with the posterior vaginal sling in an elderly population. Elderly patients with significant vaginal prolapse underwent a posterior vaginal sling using the IVS Tunneller device (Tyco Healthcare, United States Surgical, Norwalk, CT). Primary failure was defined as a postoperative pelvic organ prolapse quantitative point C (the apex of the vagina) within 2 cm of the preoperative value. Secondary failure was defined as any portion of the anterior or posterior vaginal walls protruding to or beyond the hymeneal ring (pelvic organ prolapse quantitative points Aa or Ap equal to or greater than 0). Twenty-one patients underwent the procedure; 19 were seen for follow up. The average age was 70 years (range 60-78). Twelve patients had primary or secondary failures (12 of 19, 63%). There were 5 primary failures (5 of 19, 26%) and 7 secondary failures (7 of 19, 37%). The mean time to failure was 7 weeks (range 1-18). In our elderly population, the posterior vaginal sling has a high failure rate, occurring early in the postoperative period.
Medical subject headings
- Gynecologic Surgical Procedures
- Uterine Prolapse