This is a retrospective review of 150 C2 pedicle screw placements. Candidates had their C2 pedicle morphology assessed through three-dimensional imaging, including preoperative image guidance. After surgery, the patients were serially CT scanned. Follow-up, with fusion assessment, ranged from 1 to 12 years. We will show that an open technique combined with lateral C-arm guidance provides rapid placement of C2 pedicle screws. C2 pedicle screws can be successful anchors for a variety of cervical problems. Standard intraoperative image guidance, biplane fluoroscopy, or free hand techniques all have their drawbacks. After adequate C2 exposure, the C2 pedicle is palpated. The dissector remains stationary to provide coronal orientation while a lateral C-arm radiograph is obtained for sagittal orientation. The drill trajectory is set, the C2 pedicle cannulated, and a cancellous screw placed. A total of 71 patients had bilateral screws placed and 8 patients had unilateral screws placed. The overall complication rate was 2.7%. In our series, we have found a consistent way to cannulate the C2 pedicle. C2 fixation serves as an integral part of cervical reconstruction. Preoperative planning, anatomic knowledge, and lateral C-arm orientation create a low morbidity method for C2 screw placement.
Medical subject headings
- Bone Screws
- Cervical Vertebrae
- Prosthesis Implantation
- Spinal Fusion
Anatomy
- cervical spine